Data center fire suppression

Data center fire suppression comes in four families: halocarbon clean agents (FM-200 and FK-5-1-12), inert gases, water mist and preaction sprinklers, with VESDA-style aspirating detection giving the earliest warning in front of all of them. Of the 38 companies here, 15 sell inert gas, 10 name a halocarbon agent, 11 sell water mist, 17 offer aspirating detection and 6 state FM Approval.

38 companies 60 sources, each dated Checked

AQUASYS Technik———Yes———Linz, Austria2026-11-11
Bryland Fire ProtectionInstaller / serviceYes———Yes—Dudley, UK2026-11-11
Chubb Fire & SecurityInstaller / service———————2026-11-11
ConvergintInstaller / service———————2026-11-11
COSCO Fire ProtectionInstaller / service———————2026-11-11
FikeManufacturerYesYesYes—Yes——2026-11-11
Fire Eater——Yes————Hillerød, Denmark2026-11-11
Fireaway (Stat-X)Manufacturer—————NoMinnetonka, Minnesota, United States2026-11-11
Firetrace InternationalManufacturer———————2026-11-11
FOGTECManufacturer and installerYesYesYes—Yes—Cologne, Germany2026-11-11
Fortis Fire & Safety (including VFS)Installer / service———YesYes——2026-11-11
Gielle IndustriesInstaller / service—Yes—————2026-11-11
Honeywell Xtralis (VESDA)Manufacturer————Yes——2026-11-11
Janus Fire SystemsManufacturerYesYes——Yes—Crown Point, Indiana, United States2026-11-11
Johnson Controls (Ansul, Tyco, LPG)Manufacturer and installerYesYesYesYesYes——2026-11-11
Kidde Fire Systems (KiddeFenwal)ManufacturerYesYes——Yes——2026-11-11
Koorsen Fire & SecurityInstaller / service————Yes——2026-11-11
Marioff (HI-FOG)Manufacturer and installer——YesYes—YesVantaa, Finland2026-11-11
MinimaxManufacturerYesYesYes—Yes——2026-11-11
NAFFCOManufacturer and installer—Yes———YesJebel Ali Free Zone, Dubai, UAE2026-11-11
Nohmi BosaiManufacturer and installer—Yes————Tokyo, Japan2026-11-11
NOTIFIER by Honeywell—————Yes—Northford, Connecticut, USA2026-11-11
ORR ProtectionInstaller / service——Yes—Yes——2026-11-11
Protec Fire and Security GroupManufacturer and installer——Yes———Nelson, United Kingdom2026-11-11
Pye-Barker Fire & SafetyInstaller / service———————2026-11-11
Reliable Automatic SprinklerManufacturer———Yes—YesLiberty, South Carolina, USA2026-11-11
Rotarex FiretecManufacturerYesYes———YesLintgen, Luxembourg2026-11-11
Saval—Yes——————2026-11-11
Sciens Building SolutionsInstaller / service————Yes——2026-11-11
Scutum——YesYes—Yes——2026-11-11
Securiton AG—————Yes—Zollikofen, Switzerland2026-11-11
SEVO SystemsManufacturerYes—————Lenexa, Kansas, United States2026-11-11
Siemens (Sinorix)Manufacturer—YesYes———Zug, Switzerland2026-11-11
Summit Fire ProtectionInstaller / service————Yes——2026-11-11
Ultra Fog———Yes———Kungsbacka, Sweden2026-11-11
Victaulic (Vortex)Manufacturer—————YesEaston, Pennsylvania, USA2026-11-11
Viking GroupManufacturer—Yes—Yes—YesMichigan, USA2026-11-11
WAGNER GroupManufacturer—Yes——Yes——2026-11-11

Novec 1230: what changed

Clean agent suppliers

3M, the original maker of Novec 1230, set the end of 2025 to stop making all fluorinated fluids and exit PFAS manufacturing. FK-5-1-12 systems still ship under system makers’ own names, so every row here lists the agent as the company names it today. Ask each bidder for the agent’s chemical name, its supplier and the refill source.

How this table is built

Full methodology

Every value comes from the company’s own pages, datasheets or a named trade source. The small number next to a figure opens that source. A dash means the cited page does not say, not that the company lacks it.

Each row carries the date we last checked it, and the newest check was 11 Nov 2026. Spot a stale claim? Email hello@firesuppressioncompanies.com with the source and we update the row.

Free to reuse under CC BY 4.0 with a link to this page: CSV, JSON, llms.txt.

Questions buyers ask

What are the main ways to protect a data hall from fire?

Four families cover almost every data hall: halocarbon clean agents (FM-200 and FK-5-1-12), inert gases (nitrogen, argon and blends such as IG-541), water mist, and preaction sprinklers. Aspirating smoke detection such as VESDA sits in front of all of them and gives the earliest warning. In this table, 15 companies sell inert gas, 10 name a halocarbon agent, 11 sell water mist, 5 sell preaction sprinklers and 17 offer aspirating detection.

Sources: Johnson Controls data center fire protection, Fike data center protection, Minimax data center solutions

Is Novec 1230 still available?

3M, the original maker of Novec 1230, announced in December 2022 that it would stop making all fluorinated fluids and exit PFAS manufacturing by the end of 2025. The same FK-5-1-12 agent now comes from system makers under their own names: Fike sells SF 1230 as a one-to-one drop-in Novec 1230 replacement, Minimax sells MX 1230, Rotarex builds RX5112 on FK-5-1-12, and Saval lists FK-5-1-12 “formerly Novec 1230”. Ask any bidder which fluid fills the cylinders and who supplies the refill.

Sources: 3M PFAS exit announcement, December 2022, 3M Form 10-Q, September 2026, Fike SF 1230, Minimax MX 1230, Rotarex RX5112, Saval FK-5-1-12

Which suppression systems are quietest on discharge?

Four companies publish low-noise discharge hardware. Kidde’s NATURA acoustic nozzles hold discharge below 110 dB across 500 Hz to 10 kHz, measured 1 m from the nozzle. Wagner’s FirExting SILENT, Siemens’ Sinorix Silent Extinguishing Technology and Nohmi’s PNQ/ZMQ nozzles target the same problem on inert-gas systems. Ask for the test distance and frequency band, as Kidde publishes.

Sources: Kidde data centers, Wagner data centers, Nohmi NN100

Can I protect a single rack or electrical cabinet?

Yes. Firetrace’s in-cabinet systems activate on their own and need no electricity, with an optional pressure switch to tie into emergency power off. SEVO’s SMART Cabinet FDS is a 2U, 19-inch FK-5-1-12 unit with twin optical smoke detectors. Rotarex’s FireDETEC and Minimax’s CPS 1230 protect individual cabinets as well.

Sources: Firetrace server room protection, SEVO SMART Cabinet FDS, Rotarex FireDETEC

Is condensed aerosol a clean agent?

No. Stat-X states that it is a condensed aerosol, not a clean agent. It is listed by UL and ULC to UL 2775, its generators have a 15-year service life, and no condensed aerosol system currently carries FM Approval. For server rooms its guidance says to shut down IT ventilation fans before release, because particles can accumulate inside equipment.

Sources: Stat-X FAQ, Stat-X aerosol protection in server rooms

How much water does water mist save?

Marioff and Protec both advertise up to 90% less water; the claim is theirs, so ask for the comparator in your design. Victaulic’s Vortex discharges water and nitrogen from one emitter and says it does not need tight room integrity, with FM approval for above-raised-floor data processing halls.

Sources: Marioff HI-FOG data centers, Protec data centres, Victaulic Vortex